Diesel Data: Automotive Repair

Select Arm Clearance Inspection

Select Arm Clearance Inspection
1. Measure clearance between the select arm (A) and interlock (B) with a feeler gauge (C). If the clearance is more than the service limit, go to step 2.





2. Measure width of the select arm.
^ If the width is not within the standard, replace the select arm.
^ If the width is within the standard, replace the interlock.