Thermostat: Service and Repair
Thermostat Replacement (RPO LE5)
Removal Procedure
1. Remove the intake manifold cover.
2. Drain the cooling system.
3. Reposition the radiator outlet hose clamp (1) at the thermostat cover.
4. Remove the radiator outlet hose from the thermostat cover.
5. Reposition the radiator surge tank outlet hose clamp (1) at the thermostat cover.
6. Remove the radiator surge tank outlet hose from the thermostat cover.
7. Remove the thermostat cover bolts and cover.
8. Remove the thermostat.
9. Remove and discard the thermostat cover O-ring seal.
Installation Procedure
1. Install a NEW thermostat cover O-ring seal.
2. Install the thermostat.
3. Notice: Refer to Fastener Notice in Service Precautions.
Install the thermostat cover bolts.
^ Tighten the bolts to 10 Nm (89 inch lbs.).
4. Install the radiator surge tank outlet hose to the thermostat cover.
5. Position the radiator surge tank outlet hose clamp (1) at the thermostat cover.
6. Install the radiator outlet hose to the thermostat cover.
7. Position the radiator outlet hose clamp (1) at the thermostat cover.
8. Fill the cooling system.
9. Install the intake manifold cover.