Blower Motor: Service and Repair
Blower Motor Replacement
Removal Procedure
1. Remove the right closeout panel. Refer to Instrument Panel Insulator Panel Replacement - Right Side (Service and Repair) .
2. Remove the blower motor wire harness connector.
Important: Cut through the case as straight as possible because the motor cup must be replaced. In order to prevent damage to the component, do not cut any deeper than necessary to remove the motor cup.
3. Cut out the blower motor using a utility knife in the narrow groove of the lower case.
4. Remove the blower motor.
Installation Procedure
1. Install the motor blower seal.
2. Install the blower motor.
3. Install the blower motor attachment ring if reusing the blower motor.
Notice: Refer to Fastener Notice (Fastener Notice) .
4. Tighten the blower motor screws.
Tighten the screws to 1.5 N.m (13 lb in).
5. Install the blower motor wire harness connector.
6. Install the right closeout panel. Refer to Instrument Panel Insulator Panel Replacement - Right Side (Service and Repair) .