P0A3B
DTC P0A3B
Diagnostic Instructions
* Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. Initial Inspection and Diagnostic Overview
* Review Strategy Based Diagnosis for an overview of the diagnostic approach.
* Diagnostic Procedure Instructions provides an overview of each diagnostic category.
DTC Descriptor
DTC P0A3B
- Starter/Generator Overtemperature
Circuit/System Description
The starter/generator control module (SGCM) monitors the motor generator unit (MGU) temperature sensor for an overtemperature condition.
Conditions for Running the DTC
The engine is running.
Conditions for Setting the DTC
MGU temperature is greater than 205°C (401°F) for 1 second.
Action Taken When the DTC Sets
Stop PWM (MGU shutdown)
Conditions for Clearing the DTC
MGU temperature is less than 150°C (212°F) for 3 seconds.
Diagnostic Aids
Possible MGU fan failure caused by obstructions, blockage to the vents or damaged fan.
Circuit/System Testing
Caution: To help avoid personal injury, additional precautions must be taken prior to working on the generator control module or the generator starter. After removing the 36V battery cables from the generator battery, remove both engine wiring harness connectors from the generator control module. Wait at least 5 minutes and then remove the generator control module cover. Verify voltage levels at all 36V, 12V, and 3-phase connections, are less than 3 volts using a DMM before proceeding.
1. Perform the Hybrid Battery Service Disconnect/Connect. Service and Repair
2. Inspect the connection of 3 phase cables for the proper torque.
If the 3 phase cables are within torque specifications, replace the MGU.
Repair Instructions
Perform the Diagnostic Repair Verification after completing the diagnostic procedure. Verification Tests
Generator with Starter Replacement for MGU replacement