Service Port HVAC: Service and Repair
Air Conditioning Refrigerant Service Valve Core Replacement
Special Tools
* GE-39400-A - Halogen Leak Detector
* GE-46246 - Valve Core Removal Tool
For equivalent regional tools, Refer to Special Tools Tools and Equipment
Removal Procedure
1. Recover the refrigerant. Refer to Refrigerant Recovery and Recharging (High Voltage Electric Compressor) Refrigerant Recovery and Recharging (High Voltage Electric Compressor).
2. Use GE-46246 - Valve Core Removal Tool or equivalent to remove the valve core.
Installation Procedure
1. Use GE-46246 - Valve Core Removal Tool or equivalent to install and tighten the valve core.
2. Evacuate and charge the A/C system. Refer to Refrigerant Recovery and Recharging (High Voltage Electric Compressor) Refrigerant Recovery and Recharging (High Voltage Electric Compressor).
Note:
To prevent loss of refrigerant charge, tighten the cap. Replace the cap if the seal is missing or damaged.
3. Test the affected A/C fittings for leaks using GE-39400-A - Halogen Leak Detector.