With A/C
Evaporator and Blower Assembly Component View:
NOTE: The blower resistor is mounted on the blower side of the blower-evaporator case.
REMOVE OR DISCONNECT
1. Negative battery cable.
2. Electrical connection.
3. Screws (144).
4. Resistor (145).
INSTALL OR CONNECT
1. Resistor (145).
2. Screws (144).
3. Electrical connection.