With A/C
Evaporator and Blower Assembly Component View:
Accumulator Replacement:
Evaporator and Blower Case Replacement:
Control Assembly Replacement:
REMOVE OR DISCONNECT
1. Negative battery cable.
2. Refrigerant from the system.
3. Electrical connections.
4. Refrigerant outlet line (109) from the accumulator (4).
^ Cap or plug open lines.
5. Case flange screws (139) and nuts (147).
6. Blower case (140) with the accumulator (4).
IMPORTANT: Drain refrigerant oil from the accumulator into a clean container. Measure and add new oil.
INSTALL OR CONNECT
1. Blower case (140) with the accumulator (4).
IMPORTANT: Add 0.057 kg (2 oz.) of clean refrigerant oil PLUS an amount equal to that drained.
2. Refrigerant inlet line (108) to the accumulator (4).
IMPORTANT: Add 0.057 kg (2 oz.) of clean refrigerant oil PLUS an amount equal to that drained.
^ Use clean 525 viscosity refrigerant oil on the seal.
^ Tighten connector to 24 Nm (18 ft. lbs.).
3. Electrical connection (154).
4. Negative battery cable.
5. Refrigerant to the system.
^ Evacuate, charge and leak test.