Diesel Data: Automotive Repair

Auxiliary Blower Motor: Service and Repair



Auxiliary Blower Motor Replacement

Removal Procedure

1. Remove the auxiliary HVAC module.
2. Disconnect the electrical connectors from the auxiliary blower motor.




3. Remove the screws (1) from the auxiliary blower motor.
4. Remove the auxiliary blower motor (2).
5. Remove the retaining clip from the fan cage.
6. Remove the fan cage from the auxiliary blower motor.

Installation Procedure




1. Install the fan cage to the auxiliary blower motor.
2. Install the retaining clip to the fan cage.
3. Install the auxiliary blower motor.

Notice: Refer to Fastener Notice.

4. Install the screws (1) to the auxiliary blower motor (2).

Tighten the screws to 5 N.m (44 lb in).

5. Connect the electrical connectors to the auxiliary blower motor.
6. Install the auxiliary HVAC module.