Diesel Data: Automotive Repair

Driver Squib Terminal Shorted to Ground (Active)

Test 18 - 19:




Test 20 - 21:




SYMPTOM
DRIVER SQUIB TERMINAL SHORTED TO GROUND (ACTIVE)


WHEN MONITORED
Continuously with the ignition on.

SET CONDITION
With voltage on, the driver airbag line 1 or line 2 circuit(s) is other than expected.

POSSIBLE CAUSES
- Driver airbag line 1 or line 2 short to ground
- Clockspring short to ground
- Driver side airbag module internal short to ground
- ACM DEF, driver airbag terminal short to ground