Refrigerant Pressure Sensor / Switch, HVAC
Refrigerant Pressure Sensor / Switch, HVAC
Low psi control = Pressure Transducer to PCM = opens <29.4 psi
High psi control = Pressure Transducer to PCM = opens >431 psi