Lamp Out Indicator: Testing and Inspection
LAMP OUTAGE INDICATOR CIRCUITLamp Outage Indicator Circuit:
WHEN MONITORED
With the ignition on.
SET CONDITION
Lamp Outage Indicator circuit failure between the Illumination Control Module and the Instrument Cluster.
POSSIBLE CAUSES
- Indicator circuit open
- Indicator lamp
- Illumination control module
- Instrument cluster
DIAGNOSTIC TEST
1. THE LAMP OUTAGE INDICATOR LAMP/INSTRUMENT CLUSTER
Turn the ignition off.
Disconnect the Instrument Cluster C1 harness connector.
NOTE: Check connectors - Clean/repair as necessary.
Turn the ignition on.
Measure the voltage of the Lamp Outage Indicator circuit at the Instrument Cluster C1 harness connector.
Q: Is the voltage above 10 volts?
YES: Inspect the Lamp Outage Indicator Lamp. If OK, replace the Instrument Cluster.
Perform BODY VERIFICATION TEST. Body Verification Test
NO: Go to 2
2. MEASURE LAMP OUTAGE INDICATOR CIRCUIT RESISTANCE
Turn the ignition off.
Disconnect the Illumination Control Module harness connector.
NOTE: Check connectors - Clean/repair as necessary.
Measure the resistance of the Lamp Outage Indicator circuit from the Illumination Control Module D harness connector to the Instrument Cluster C1 harness connector.
Q: Is the resistance below 5.0 ohms?
YES: Replace the Illumination Control Module.
Perform BODY VERIFICATION TEST. Body Verification Test
NO: Repair the Lamp Outage Indicator circuit for an open.
Perform BODY VERIFICATION TEST. Body Verification Test