P0498
Test 1 - 2:
Test 3 - 5:
SYMPTOM
P0498-NVLD CANISTER VENT VALVE SOLENOID CIRCUIT LOW
WHEN MONITORED
Engine running.
SET CONDITION
The PCM detects a short in the NVLD canister vent solenoid circuits. One trip Fault.
POSSIBLE CAUSES
- Good trip equal to zero
- Vehicle history and service bulletin investigation
- NVLD solenoid
- NVLD SOL control circuit shorted to ground
- PCM