Diesel Data: Automotive Repair

Short Runner Valve Solenoid






INSTALLATION





1. Install the Sort Runner Valve. Align the slot in the valve with the tab on the intake manifold shaft.
2. Install the 2 mounting bolts.
3. Tighten bolts to 2.8 Nm (25 in. lbs.).





4. Connect the electrical connector.
5. Connect negative battery cable.