Diesel Data: Automotive Repair

B220B






B220B-OCCUPANT RESTRAINT CONTROLLER FIRING STORED ENERGY

For a complete wiring diagram, refer to the Wiring Information.

Theory of Operation
When powered, the Occupant Restraint Controller (ORC) performs an internal self test. The repair of this fault condition does not involve any external circuitry and centers on verifying the integrity of the module's internal circuitry and software validity.
- When Monitored:
The ORC checks the status of firing stored energy circuit at power up during the initialization process, and continuously through the ignition cycle.

- Set Condition:
This DTC sets when a fault is detected internal to ORC firing stored energy circuit. Once set, this DTC is latched for an entire power cycle. If the same failure is detected in two consecutive cycles, this DTC is latched active indefinitely.





Always Perform the Pre-Diagnostic Troubleshooting procedure before proceeding. Restraints System Pre-Diagnostic Procedure.
REPLACE OCCUPANT RESTRAINT CONTROLLER (ORC)
1. Turn the ignition on.
2. With the scan tool, erase and read ORC DTCs.

WARNING: To avoid serious or fatal injury, turn the ignition off, disconnect the battery and wait two minutes before proceeding.

WARNING: If the Occupant Restraint Controller is dropped at any time, it must be replaced. Failure to take proper precautions can result in accidental airbag deployment and serious or fatal injury.

When this code is set, view repair.

Repair

- Replace the Occupant Restraint Controller (ORC).