B2213
B2213-CCN INTERNAL
For a complete wiring diagram refer to the Wiring Information.
- When Monitored:
With the Instrument Cluster awake.
- Set Condition:
The Instrument Cluster detects an internal failure.
VERIFY INSTRUMENT CLUSTER OPERATION
1. With the scan tool, read Cluster DTCs.
Is this DTC active?
YES
- Replace the Instrument Cluster.
- Perform BODY VERIFICATION TEST - VER 1. Body Verification Test
NO
- Test complete.