Diesel Data: Automotive Repair

Thermostat: Service and Repair

Thermostat - 2.0L- Zetec

Removal
1. Drain the cooling system.





2. Disconnect the coolant hoses.





3. Remove the thermostat cover bolts.





4. Remove the thermostat.





5. Remove and discard the rubber seal.

Installation





1. NOTE: Install a new rubber seal.

To install, reverse the removal procedure.
2. Fill and bleed the cooling system.