Air Door Cable: Description and Operation
AIR DISTRIBUTION OPERATING CABLESNOTE: The Bowden cables for LHD and RHD vehicles are identical. However, they are fastened to the air flap operating mechanism with the respective reverse side of their connectors.
The air distribution switch operates with two Bowden cables. The cables operate the air distribution valves in the heater housing.
To remove and install the cables, the rotary switch must be turned as far as it will go to the left. The air flap mechanism engages easily in this position, making the installation of the cables easier.