Disassembly and Assembly
HEATER CORE HOUSINGDISASSEMBLY
1. Detach the floor level ventilation hose.
- Pull off the hose.
2. Separate the heater/heat exchanger housing parts.
- Undo the two bolts.
- Undo seven retaining tangs.
3. Remove the heat exchanger.
4. Pull out the heat exchanger.
5. Separate the heater/blower housing parts.
1 Undo the two bolts.
2 Undo four retaining tangs.
6. Separate the blower/recirculated air housing parts.
- Undo nine retaining tangs.
7. Dismantle the air recirculation housing.
- Release the five retaining tabs.
8. Remove the air deflector.
9. Separate the heater/evaporator housing.
- Undo 11 retaining tangs.
ASSEMBLY
1. NOTE:
- When assembling, ensure that the guide pins are seated correctly.
- Replacement steel clips must be used if the housing is not properly sealed after assembly or the retaining tangs are broken.
Assemble the components in the reverse order.