Test D: No Power in START
Pinpoint Test D: No Power in STARTRefer to Wiring Diagrams Vehicle/Diagrams, Power Distribution/SJB for schematic and connector information.
Normal Operation
When the ignition switch is turned to the START position, fused battery voltage is sent to the smart junction box (SJB) along circuit 1522 (DG).
This pinpoint test is intended to diagnose the following:
^ Wiring, terminals or connectors
^ Ignition switch
^ SJB