Evaporator to Compressor Suction Line
Evaporator to Compressor Suction Line
Removal and Installation
1. Recover the refrigerant.
2. Remove the A/C compressor suction fitting nut and disconnect the fitting.
- Discard the O-ring seal and gasket seal.
- To install, tighten to 15 Nm (133 lb-in).
3. Remove the evaporator-to-compressor suction outlet line fitting nut and disconnect the fitting.
- Discard the O-ring seal and gasket seal.
- To install, tighten to 15 Nm (133 lb-in).
4. Remove the evaporator-to-compressor suction line.
5. To install, reverse the removal procedure.
- Install new gasket seals and O-ring seals.
- Lubricate the refrigerant system with the correct amount of clean PAG oil.
6. Evacuate, leak test and charge the refrigerant system.