Thermostatic Expansion Valve
Thermostatic Expansion Valve
Removal and Installation
1. Recover the refrigerant. For additional information, refer to Climate Control System - General Information and Diagnostics Air Conditioning (A/C) System Recovery, Evacuation and Charging.
2. Remove the 2 Thermostatic Expansion Valve (TXV) fitting nuts and disconnect the fittings.
- Discard the O-ring seals.
- To install, tighten to 10 Nm (89 lb-in).
3. Remove the 2 TXV bolts.
- To install, tighten to 8 Nm (71 lb-in).
4. Remove the TXV.
- Discard the O-ring seals.
5. To install, reverse the removal procedure.
- Install new O-ring seals.
- Add the correct amount of clean PAG oil to the refrigerant system. For additional information, refer to Climate Control System - General Information and Diagnostics Service and Repair.
6. Evacuate, leak test and charge the refrigerant system. For additional information, refer to Climate Control System - General Information and Diagnostics Air Conditioning (A/C) System Recovery, Evacuation and Charging.