Expansion Valve: Service and Repair
Thermostatic Expansion Valve
Removal and Installation
1. Recover the refrigerant.
2. Remove the 2 Thermostatic Expansion Valve (TXV) fitting nuts and disconnect the fittings.
- Discard the O-ring seals.
- To install, tighten to 10 Nm (89 lb-in).
3. Remove the 2 TXV (Thermostatic Expansion Valve) bolts.
- To install, tighten to 8 Nm (71 lb-in).
4. Remove the TXV (Thermostatic Expansion Valve).
- Discard the O-ring seals.
5. To install, reverse the removal procedure.
- Install new O-ring seals.
- Add the correct amount of clean PAG oil to the refrigerant system.
6. Evacuate, leak test and charge the refrigerant system.