Climate Control - DATC
Thermostatic Expansion Valve
WARNING: Before beginning any service procedure, REFER to Safety Warnings . Failure to follow this instruction may result in serious personal injury.
Material(s)
Exploded View
Removal
1. Recover the refrigerant. REFER to Air Conditioning (AC) System Recovery, Evacuation and Charging .
2. Position aside the TXV (Thermostatic Expansion Valve) manifold and tube assembly.
1. Disconnect the A/C (Air Conditioning) pressure transducer.
2. Remove the TXV (Thermostatic Expansion Valve) fitting nut and disconnect the fitting.
- Discard the O-ring seals.
- To install, tighten to 11 Nm (97 lb-in).
3. Remove the TXV (Thermostatic Expansion Valve) bolts and remove the TXV (Thermostatic Expansion Valve).
- Discard the O-ring seals.
- To install, tighten to 8 Nm (71 lb-in).
Installation
1. To install, reverse the removal procedure.
- Install new O-ring seals and gasket seals.
- If filtering of the refrigerant system is not to be carried out, add the correct amount of clean PAG oil to the refrigerant system. REFER to Refrigerant Oil Adding .
2. If filtering of the refrigerant system is not to be carried out, evacuate, leak test and charge the refrigerant system. REFER to Air Conditioning (AC) System Recovery, Evacuation, and Charging .