Power Mirror Actuator Test
Power Mirror Actuator Test
1. Remove the door panel Service and Repair.
2. Disconnect the 6P connector (A) from the power mirror.
3. At the 13P connector check actuator operation by connecting power and ground according to the table.
4. If the mirror fails to work properly, replace the power mirror actuator.
Defogger Test
5. Check for continuity between the power mirror actuator 6P connector terminals No. 1 and No. 2. There should be continuity. If there is no continuity, check for an open in the wire between the mirror actuator 6P connector and the mirror holder terminals. If the wire harness is OK, replace the mirror holder Mirror Holder Replacement.