Immobilizer Indicator Does Not Go Off




Immobilizer System Symptom Troubleshooting - Immobilizer indicator does not go off

Immobilizer indicator does not go off

1. Turn the ignition switch to LOCK (0).

2. Connect the HDS to the data link connector.

3. Turn the ignition switch to ON (II).

4. Enter IMMOBI, then select IMMOBILIZER SET UP, them select System Check, Number of keys, and Status Log.

5. Do the SYSTEM CHECK with the HDS.

Is N-1 OK indicated?

YES -

Replace the gauge control module.� Gauge Control Module Replacement

NO -

Substitute a known-good immobilizer-keyless control unit, then register it and recheck. If the symptom goes away, replace the original immobilizer-keyless control unit.� Service and Repair