VSA Off Switch Does Not work (VSA Cannot be Turned OFF)
VSA System Symptom Troubleshooting - VSA OFF switch does not work (VSA cannot be turned OFF)
VSA OFF switch does not work (VSA cannot be turned OFF) ('10-11 models)
1. Turn the ignition switch to LOCK (0).
2. Check the VSA OFF switch.
Is the VSA OFF switch OK?
YES -
Go to step 3.
NO -
Replace the VSA OFF switch Testing and Inspection.�
3. Disconnect the VSA OFF switch 5P connector.
4. Disconnect the gauge control module 36P connector.
5. Check for continuity between VSA OFF switch 5P connector terminal No. 2 and body ground.
Is there continuity?
YES -
Repair a short to body ground between the gauge control module and the VSA OFF switch.�
NO -
Substitute a known-good gauge control module Gauge Control Module Replacement, then go to step 1 VSA Off Switch Does Not work (VSA Cannot be Turned OFF) and recheck. If it is OK, replace the original gauge control module Gauge Control Module Replacement.�