The A/C Condenser and Radiator Fans are Inoperative With the A/C On. The Blower and Heater Controls Work Normally
The A/C condenser and radiator fans are inoperative with the A/C on. The blower and heater controls work normally
The A/C condenser and radiator fans are inoperative with the A/C on. The blower and heater controls work normally
Probable cause: Radiator/A/C condenser fan common circuit malfunction
Do the radiator and A/C condenser fan common circuit troubleshooting Radiator and A/C Condenser Fan Common Circuit Troubleshooting
Also check for
HVAC DTCs Initial Inspection and Diagnostic Overview
Also check for
Powertrain DTCs Initial Inspection and Diagnostic Overview
Also check for
Poor ground at G201; '07-08 models except SC, '07-08 SC models, '09-11 models
Also check for
Poor or loose connections at the terminals