A/C Condenser Fan Circuit Troubleshooting
A/C Condenser Fan Circuit Troubleshooting
NOTE: Do not use this troubleshooting procedure if the radiator fan and/or the A/C compressor is inoperative. Refer to the symptom troubleshooting index.
1. Check the No. 1 (30 A) fuse in the under-hood fuse/relay box, and the No. 14 (10 A) fuse in the under-dash fuse/relay box.
Are the fuses OK?
YES -
Go to step 2.
NO -
Replace the fuse(s), and recheck. If either fuse blows again, check for a short in the No. 1 (30 A) or No. 14 (10 A) fuse circuits.�
2. Remove the A/C condenser fan relay from the under-hood fuse/relay box, and test it.
Is the relay OK?
YES -
Go to step 3.
NO -
Replace the A/C condenser fan relay.�
3. Measure the voltage between A/C condenser fan relay 4P socket terminal No. 2 and body ground.
Is there battery voltage?
YES -
Go to step 4.
NO -
Replace the under-hood fuse/relay box Under-Hood Fuse/Relay Box Removal and Installation.�
4. Connect A/C condenser fan relay 4P socket terminals No. 1 and No. 2 with a jumper wire.
Does the A/C condenser fan run?
YES -
Go to step 5.
NO -
Go to step 8.
5. Disconnect the jumper wire.
6. Turn the ignition switch to ON (II).
7. Measure the voltage between A/C condenser fan relay 4P socket terminal No. 3 and body ground.
Is there battery voltage?
YES -
Replace the under-hood fuse/relay box Under-Hood Fuse/Relay Box Removal and Installation.�
NO -
Repair an open in the BLK/YEL wire between the No. 14 (10 A) fuse in the under-dash fuse/relay box and the A/C condenser fan relay socket in the under-hood fuse/relay box.�
8. Disconnect the jumper wire.
9. Disconnect the A/C condenser fan motor 2P connector.
10. Check for continuity between A/C condenser fan relay 4P socket terminal No. 1 and A/C condenser fan motor 2P connector terminal No. 2.
Is there continuity?
YES -
Go to step 11.
NO -
Repair an open in the wire between the A/C condenser fan relay socket in the under-hood fuse/relay box and the A/C condenser fan motor.�
11. Check for continuity between A/C condenser fan motor 2P connector terminal No. 1 and body ground.
Is there continuity?
YES -
Replace the A/C condenser fan motor Service and Repair.�
NO -
Check for an open in the wire between the A/C condenser fan and body ground. If the wire is OK, check for poor body ground at G201; '07-08 models except SC, '07-08 models SC, '09-11 models.�