Diesel Data: Automotive Repair

Moonroof Open Relay

NOTE: See Turn Signal/Hazard Relay Input Test.

Five-terminal type:




Check for continuity between the terminals.
- There should be continuity between the No.1 and No.2 terminals when power and ground are connected to the No.3 and No.5 terminals.
- There should be continuity between the No.2 and No.4 terminals when power is disconnected.





Moonroof open relay