Fresh Air/Recirculation Actuator




1. Disconnect the 4P connector from the recirculation control motor, and remove the wire harness clip from it.
2. Remove the two self-tapping screws and the recirculation control motor.
3. Install in the reverse order of removal. After installation, make sure the recirculation control motor rung smoothly.