Diesel Data: Automotive Repair

Thermal Limiting Fuse: Service and Repair

1. Remove the bolt, ground terminal, and connector holder.

Thermal Protector Replacement:




2. Remove the thermal protector.
Remove the residue of silicone sealant from the top of the thermal protector.

Thermal Protector Replacement:




3. Apply silicone sealant to the top of the thermal protector.
4. Install in the reverse order of removal.