Solenoid Valve Test
Solenoid Valve Test1. Disconnect the solenoid harness connector (8P).
2. Measure CVT drive pulley pressure control valve assembly resistance between solenoid harness connector terminals No. 3 and No. 7.
Standard: 3.8 - 6.8 ohms
3. Measure CVT driven pulley pressure control valve assembly resistance between terminals No. 2 and No. 6.
Standard: 3.8 - 6.8 ohms
4. Measure CVT start clutch pressure control valve assembly resistance between terminals No. 4 and No. 8.
Standard: 3.8 - 6.8 ohms
5. Measure the inhibitor solenoid resistance between terminal No. 5 and body ground.
Standard: 11.7 - 21.0 ohms
6. Replace the lower valve body assembly, if the measurement of any solenoid is out of standard.
7. If all of the resistances are within the standard, a clicking sound should be heard when connecting the battery terminals to the solenoid harness connector terminals.
^ CVT drive pulley pressure control valve assembly No. 3 to battery positive terminal No. 7 to battery negative terminal CVT driven pulley pressure control valve assembly No. 2 to battery positive terminal No. 6 to battery negative terminal CVT start clutch pressure control valve assembly No. 4 to battery positive terminal No. 8 to battery negative terminal
^ Inhibitor solenoid No.5 to battery positive terminal and body ground to negative terminal
8. If no clicking sound is heard, remove the lower valve body assembly, and check the solenoid.