Diesel Data: Automotive Repair

Countershaft Inspection

Countershaft Inspection
1. Inspect the gear and bearing surfaces for wear and damage, then measure the mainshaft at points A, B, and C. If any part of the mainshaft is less than the service limit, replace it.





2. Inspect the runout by supporting both ends of the countershaft. Rotate the countershaft two complete turns while measuring with a dial gauge. If the runout is more than the service limit, replace the countershaft.