Diesel Data: Automotive Repair

Torque Converter Housing Countershaft Bearing Replacement




Torque Converter Housing Countershaft Bearing Replacement

Special Tools Required

- Adjustable Bearing Puller, 25-40 mm 07736-A01000B
- Driver Handle, 15 x 135L 07749-0010000
- Oil Seal Driver Attachment, 58 mm 07JAD-PH80101

1. Remove the countershaft bearing using the adjustable bearing puller (20-40 mm) and a commercially available 3/8''-16 slide hammer (A).






2. Install the ATF guide plate (A).





3. Install the new countershaft bearing (B) in the housing using the driver handle and the attachment (62 x 68 mm); install the bearing outer race surface in height (C) of 0-0.03 mm (0-0.001 in) above the housing surface (D). Do not install the bearing exceeding 0.03 mm (0.001 in) high from housing surface.