Solar Sensor: Testing and Inspection
Sunlight Sensor Test
NOTE: Before testing the sensor, check for Climate control DTCs How to Troubleshoot the Climate Control System (With Climate Control).
1. Pull out the sunlight sensor (A) Service and Repair.
With automatic lighting
Without automatic lighting
2. Turn the ignition switch to ON (II). Measure the voltage between the terminals with the (+) probe on terminal No. 4 (with automatic lighting) or No. 1 (without automatic lighting) and the (-) probe on terminal No. 2 with the connector connected.
NOTE: The voltage readings will not change under the light of a flashlight or a fluorescent lamp.
Voltage should be:
- 3.56 V with no sunlight or the sensor covered up
- Less than 3.56 V with sunlight on the sensor (depending on sunlight intensity)
3. If the voltage is not as specified, replace the sunlight sensor Service and Repair.