The A/C Condenser/Radiator Fans Do Not Run At High Speed, But Do Run At Low Speed (10-12 Models) (With Climate Control)
The A/C condenser/radiator fans do not run at high speed, but do run at low speed ('10-12 models)
Probable cause: Malfunction in the fan(s) high speed circuit(s)
Do the following troubleshooting as needed: A/C condenser fan high speed circuit troubleshooting A/C Condenser Fan High Speed Circuit Troubleshooting
Radiator fan high speed circuit troubleshooting Radiator Fan High Speed Circuit Troubleshooting
Also Check for
Climate control DTCs How to Troubleshoot the Climate Control System (With Climate Control)
Also Check for
Powertrain DTCs
Also Check for
Blown fuses No. 3-8 (30 A) and No. 3-6 (30 A) in the under-hood fuse/relay box
Also Check for
Poor ground at G301
Also Check for
Poor or loose connections at the terminals