The A/C Condenser/Radiator Fans Do Not Run At Low Speed With The A/C On, But The Blower And Heater Controls Work Normally
The A/C condenser/radiator fans do not run at low speed with the A/C on, but the blower and heater controls work normally ('10-12 models)
Probable cause: A/C condenser/radiator fan low speed circuit malfunction
Do the radiator and A/C condenser fan low speed circuit troubleshooting Radiator and A/C Condenser Fan Low Speed Circuit Troubleshooting
Probable cause: A/C pressure sensor circuit malfunction
Do the A/C pressure sensor troubleshooting:
A/C pressure sensor circuit low voltage DTC Troubleshooting
A/C pressure sensor circuit high voltage DTC Troubleshooting
NOTE: The A/C pressure sensor can malfunction without setting a DTC
Also Check for
Climate control DTCs How to Troubleshoot the Climate Control System (With Climate Control)
Also Check for
Powertrain DTCs
Also Check for
Blown fuse No. 3-8 (30 A) in the under-hood fuse/relay box
Also Check for
Poor ground at G302
Also Check for
Poor or loose connections at the terminals