VSA System
Control System DTCs
VSA DTC Troubleshooting: 66-11, 66-13
DTC 66-11 : Pressure Sensor Circuit Malfunction
DTC 66-13 : Pressure Sensor Malfunction
NOTE: Before you troubleshoot, record all freeze data and any on-board snapshot, and review the general troubleshooting information Reading and Clearing Diagnostic Trouble Codes.
1. Problem verification:
Problem verification
-1. Turn the ignition switch to ON (II).
-2. Clear the DTC with the HDS.
-3. Turn the ignition switch to LOCK (0), then turn it to ON (II) again.
-4. Check for DTCs with the HDS.
Is DTC 66-11 or 66-13 indicated?
-YES- The failure is duplicated. Go to step 2.
-NO- Intermittent failure, the system is OK at this time. Refer to intermittent failures troubleshooting.
2. VSA modulator-control unit check (update):
VSA modulator-control unit check (update)
-1. Turn the ignition switch to LOCK (0).
-2. Update the VSA modulator-control unit if it does not have the latest software Programming and Relearning.
-3. Turn the ignition switch to LOCK (0), then turn it to ON (II) again.
-4. Check for DTCs with the HDS.
Is DTC 66-11 or 66-13 indicated?
-YES- Check for loose terminals in the VSA modulator-control unit 22P connector. If the VSA modulator-control unit was updated and the symptom/indication is still present, replace the VSA modulator-control unit Service and Repair.
-NO- Troubleshooting is complete. If any other DTCs are indicated, go to the indicated DTCs troubleshooting.