With Climate Control
The A/C condenser/radiator fans do not run at low speed with the A/C on, but the blower and heater controls work normally
The A/C condenser/radiator fans do not run at low speed with the A/C on, but the blower and heater controls work normally
Probable cause: A/C condenser/radiator fan low speed circuit malfunction
Do the radiator and A/C condenser fan low speed circuit troubleshooting Radiator And A/C Condenser Fan Low Speed Circuit Troubleshooting
Probable cause: A/C pressure sensor circuit malfunction
Do the A/C pressure sensor troubleshooting:
A/C pressure sensor circuit low voltage DTC Troubleshooting
A/C pressure sensor circuit high voltage DTC Troubleshooting
NOTE: The A/C pressure sensor can malfunction without setting a DTC
Also check for
Climate control DTCs How to Troubleshoot the Climate Control System
Also check for
Powertrain DTCs
Also check for
Blown fuse No. A3-6 (MAIN FAN) (30 A) in the under-hood fuse/relay box
Also check for
Poor ground at G301
Also check for
Poor or loose connections at the terminals