Daytime Running Lamp: Service and Repair
DAYTIME RUNNING LAMP REPLACEMENTREMOVAL PROCEDURE
1. Remove the electrical connector.
2. Remove the nuts from the rear of the lamp assembly.
3. Disengage the clips retaining lamp.
4. Remove the lamp assembly.
5. Remove the bulb socket by turning the socket counter clockwise.
6. Remove the bulb.
INSTALLATION PROCEDURE
1. Install the bulb.
2. Install the bulb socket by turning the socket clockwise.
3. Install the lamp assembly.
4. Engage the clips retaining the lamp.
NOTE: Refer to Fastener Notice in Service Precautions.
5. Install the nuts to the rear of the lamp assembly.
Tighten
Tighten the nuts to 6 N.m (53 lb in).