General Information
Automatic Transaxle
P0707 Transaxle Range Switch Circuit Low Input - General Information
Component Location
General Description
The Transaxle Range Switch sends the shift lever position information to the PCM/TCM using a 12V (battery voltage) signal. When the shift lever is in the D (Drive) position the output signal of Tansaxle Range Switch is 12V and in all other positions the voltage is 0V. The PCM/TCM judges the shift lever position by reading all signals, for the Transaxle Range Switch, simultaneously.
DTC Description
The PCM/TCM sets this code when the Transaxle Range Switch has no output signal for more than 30 seconds.
DTC Detecting Condition
Schematic Diagram