Diesel Data: Automotive Repair

Component Tests and General Diagnostics





Inspection

Thermostat
1. Immerse the thermostat in water and gradually heat the water.




2. Check the valve opening temperature.

Valve opening temperature :82 °C(177 °F)
Full opening temperature :95 °C(205 °F)


If the valve opening temperature is not as specified, replace the thermostat.




3. Check the valve lift.

Valve lift :8mm(0.3in.) or more at 95 °C(205 °F)


If the valve lift is not as specified, replace the thermostat.