Component Inspection
Engine Control
P0082 Intake Valve Control Solenoid Circuit-Low (Bank 2) - Component Inspection
Component Inspection
Check OCV resistance
1. IG "OFF" and disconnect OCV connector.
2. Measure resistance between power and signal terminals of OCV. (Component Side)
Specification : 6.7 - 7.7 at 20°C (68°F)
3. Is the measured resistance within specification?
OCV Actuation Test
1. Connect GDS and IG "ON"
2. Select "Intake Oil Control Valve" on the Actuation Test
3. Activates "Intake Oil Control Valve" by pressing "START" button
(should hear a faint click from Oil Control solenoid Valve)
4. Repeat this procedure 4 or 5 times to ensure oil control solenoid valve reliability
5. Does OCV generate click sound during actuation test?