W/Harness Inspection
Engine Control
P0448 Evaporative Emission System - Vent Control Circuit Shorted - Inspection/Repair:_:W/Harness Inspection
Terminal and Connector inspection
1. Many malfunctions in the electrical system are caused by poor harness and terminal connections.
Faults can also be caused by interference from other electrical systems, and mechanical or chemical damage.
2. Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage.
3. Has a problem been found ?
Control Circuit Inspection
Check short in harness
1. IG "OFF" and disconnect CCV connector.
2. Measure resistance between power and control terminals of CCV harness connector.
Specification :Infinite
3. Is the measured resistance within specification ?