Repair Procedures
Replacement
1. Disconnect the negative (-) battery terminal.
2. Remove the heater and blower unit.
3. Remove the blower unit (A) from the heater unit after loosening a mounting bolt and 3 screws.
NOTE:
Make sure that there is no air leaking out of the blower and duct joints.
4. Installation is the reverse order of removal.