Diesel Data: Automotive Repair

Canister Purge Control Valve: Service and Repair





Inspection

1. Turn the ignition switch OFF.
2. Disconnect the PCSV connector.
3. Measure resistance between the PCSV terminals 1 and 2.
4. Check that the resistance is within the specification.

Specification:Refer to "Specification"

Removal

1. Turn the ignition switch OFF and disconnect the battery negative (-) cable.
2. Disconnect the purge control solenoid valve connector (A).
3. Disconnect the vapor hoses (B) from the purge control solenoid valve.
4. Remove the valve from the bracket.






Installation

CAUTION:
- Install the component with the specified torques.
- Note that internal damage may occur when the component is dropped. If the component has been dropped, inspect before installing.
- Be sure not to apply oil or lubricant to the end of the hoses when connecting the PCSV hose.

CAUTION:
- Be careful of foreign material not to flow into the valve.

1. Installation is reverse of removal.

Purge control solenoid valve bracket installation bolt:
9.8 - 11.8 N.m (1.0 - 1.2 kgf.m 7.2 - 8.7 lb-ft)