Variable Induction Control Actuator: Service and Repair





Inspection

1. Turn the ignition switch OFF.
2. Disconnect the VIS valve connector.
3. Measure resistance between the VIS valve terminals 1 and 2.
4. Check that the resistance is within the specification.

Specification:Refer to "Specification"

Removal

1. Turn the ignition switch OFF and disconnect the battery negative (-) cable.
2. Disconnect the variable intake solenoid valve connector (A).
3. Disconnect the vacuum hoses (B, C) from the valve.
4. Remove the installation nut (D), and then remove the valve.
[Valve 1 (Intake manifold)]




[Valve 2 (Surge tank)]






Installation

CAUTION:
- Install the component with the specified torques.
- Note that internal damage may occur when the component is dropped. If the component has been dropped, inspect before installing.

CAUTION:
- Be careful of foreign material not to flow into the valve.

1. Installation is reverse of removal.

Variable intake solenoid valve installation nut:
5.9 - 8.8 N.m (0.6 - 0.9 kgf.m, 4.3 - 6.5 lb-ft)