Diesel Data: Automotive Repair

Wastegate Solenoid: Service and Repair





Inspection

1. Turn the ignition switch OFF.
2. Disconnect the WGV connector.
3. Measure resistance between the WGV terminals 1 and 2 [B1/S1].
4. Check that the resistance is within the specification.

Specification:Refer to "Specification"

Removal

1. Turn the ignition switch OFF and disconnect the battery negative (-) cable.
2. Disconnect the waste gate solenoid valve connector (A).
3. Disconnect the vapor hoses (B) from the waste gate solenoid valve.
4. Remove the valve after removing the bolt (C).
5. Remove the waste gate solenoid valve (D).






Installation

CAUTION:
- Install the component with the specified torques.
- Note that internal damage may occur when the component is dropped. If the component has been dropped, inspect before installing.

1. Installation is reverse of removal.