Diagnosis Procedure
THE METER CONTROL SWITCH IS INOPERATIVE
Diagnosis Procedure
1.CHECK METER CONTROL SWITCH SIGNAL CIRCUIT
Check the meter control switch signal circuit. Diagnosis Procedure.
Is the inspection result normal?
YES - GO TO 2.
NO - Repair harness or connector.
2.CHECK METER CONTROL SWITCH UNIT
Perform a unit check for the meter control switch. Component Inspection.
Is the inspection result normal?
YES - Replace combination meter.
NG - Replace meter control switch.