Blower Motor Resistor Replacement - Auxiliary
Blower Motor Resistor Replacement - AuxiliaryRemoval Procedure
1. Remove the rear HVAC module assembly.
2. Disconnect the electrical connector from the blower motor control processor-auxiliary (3).
3. Remove the screws from the blower motor control processor-auxiliary (3).
4. Remove the blower motor control processor-auxiliary (3).
5. Remove the thermal gasket from the evaporator core-auxiliary surface.
Installation Procedure
1. Install the thermal gasket to the blower motor control processor-auxiliary.
2. Install the blower motor control processor-auxiliary (3).
NOTE: Refer to Fastener Notice in Cautions and Notices.
3. Install the screws to the blower motor control processor-auxiliary (3).
Tighten
Tighten the screws to 2 Nm (18 lb in).
4. Connect the electrical connector to the blower motor control processor-auxiliary (3).
5. Install the HVAC module-auxiliary.